Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Excerpt
Tip

The release of Noah System 4.15 will provide the possibility for a business system to receive an expanded set of data.

This announcement outlines the new feature at a high level.

Data Support

Noah 4.15 now makes it possible for a business system to exchange data with more data standards and newer formats. The business system can control how this new feature is utilized by setting the conformance level.

Tip

See HIMSA Data Standards for details on the available data elements per data standard

Tip

Important: If you wish to work with conformance level 4 or higher, then the result will always be that you will receive the data in the format in which it was stored in. For example, if an audiogram was stored to Noah in format 502, then WSI will send it to your system in format 502. Your system will need to be prepared work with this higher format.

If your system is configured with conformance level 3, then the data will be sent to your system in format 500. Noah will perform a runtime conversion to format 500. For example, if an audiogram was stored to Noah in format 502, then WSI will send it to your system in format 500.

Tip

WSI Installer Update - The NoahWSISetup.exe is now included with the installation of 4.15 and higher. The installer must be used and can be found in the Noah Installation directory, C:\Program Files (x86)\HIMSA\Noah 4.

Data Standard / Conformance Level

Level 3

Format

Level 4

Format

Level 5

Format

Patient demographic

Yes

Yes

Yes

Audiogram Format

500

500, 502

500, 502

Admittance Format

Note that format 500 is labeled as Impedance and 501 is Admittance. A name change in the standard was implemented with format 501. The WSI configuration screens and sample applications will only note “Impedance,” but working with level 4 or higher will provide Admittance.

500

500, 501

500, 501

Audiogram Metadata

No

500

500

Journal Entry Format

No

500

500

Real Ear Measurement Format

500

500

500

Hearing Instrument Selection

500

500

500

Cochlear Implant Sound Processor Selection

No

500

500

Hearing Instrument Fitting

500

500

500

Remote Control Format

500

500

500

Hearing Instrument Test Format

500

500

500

Journal Entry Format

No

500

500

Tinnitus

No

No

500

Notification Action

No

500

500

Scan Meta Data Standard

No

500

500

WSI will remain an effective API but will not include all data that is available in other API’s, most notably:

  • Exchange of Fast Data Views

  • Exchange of Private Action data